Rover 200, 25 and MG ZR, Cooling, Heating and Air Conditioning, Radiator, Expansion Tank & Fan, 1800cc
 
Item
Part Description
Attribute Comment
Qty
 
1  PCC104670 - Radiator assembly To YD471564 1
1  PCC107680 - Radiator assembly Air conditioning From YD471565, To 4D728652 1
1  PCC107681 - Radiator assembly - Lead Free Automatic, From 4D728653, To 5D787796 1
1  PCC001480 - Radiator assembly - Lead Free Less air conditioning Manual - Except: VVC, From 4D728653, To 5D787796 1
1 PCC001481 - Radiator assembly - Lead Free Less air conditioning Manual - Except: VVC, From 4D728653, To 5D787796 1
1  PCC107310 - Radiator assembly Air conditioning 1800 cc - Manual - MG ZR, To 4D728652 1
1  PCC107311 - Radiator assembly - Lead Free Air Conditioning - From 4D728653 - To 5D787796, VVC - From 4D728653 - To 5D787796 1
1  PCC001660 - Radiator assembly - Lead Free From 5D787797 1
2  PCU102690 - Bracket-radiator mounting - upper   2
3 PCG000050 - Mount-radiator rubber - upper   2
4 FS106127P - Screw-flanged head - M6 x 12 upper radiator bracket to body   2
5 EAP8708 - Mount-radiator rubber - lower   2
6  PGF101220 - Fan/cowl & motor assembly-cooling - Yellow To AD91696 1
6 PGF101340 - Fan/cowl & motor assembly-cooling From AD91697, To YD471564 1
6 PGF000240 - Fan/cowl & motor assembly-cooling ZR 160 160PS 1
6 PGF101840 - Fan/cowl & motor assembly-cooling - Black, 50 degrees C Air conditioning From YD471565 1
6 PGF101860 - Fan/cowl & motor assembly-cooling - Yellow, 40 degrees C Less air conditioning From YD471565 1
7 PGL100180 - Shield-cooling system fan motor   1
8 PYP100530 - Screw-self tapping AB To AD91696 3
9 CDU2958 - Nut   4
10  PCF10086 - Tank-radiator expansion To 4D779020 1
10  PCF000160 - Tank-radiator expansion coolant sensor OR Sensor not included. PCJ000040 may be required From 5D779021 1
10 PCF000161 - Tank-radiator expansion coolant sensor OR Sensor not included. PCJ000040 may be required From 5D779021 1
11  PCD100160 - Cap-expansion tank pressure   1
11 PCD100160XP - Cap-expansion tank pressure - XPart Alternative   1
12 PCU102840 - Bracket-expansion tank RHD   1
13 PCU102850 - Bracket-expansion tank LHD   1
14 YYG10006 - Screw-flanged head expansion tank to bracket   2
15 FS108167P - Screw-flanged head - M8 x 16 expansion tank bracket to body   2
16 ESR1560A - Nut & washer set - M6 expansion tank bracket to body   1
17  PEU10099 - Bracket assembly-coolant hose support To AD59500 1
17  PEU102490 - Bracket assembly-coolant hose support From AD59501, To YD471564 1
17 PEU108000 - Bracket assembly-coolant hose support From YD471565 1
18 JZV1183 - Screw - M5 x 16 hose support-fan cowl   2
19 FS106127P - Screw-flanged head - M6 x 12 bracket mounting rad lower To 5D644944 2
19 FS106125 - Screw-flanged head - M6 x 12 From 5D644945 2
20 PCU10013 - Bracket-radiator mounting - lower From 5D644945 1
900 PCJ000040 - Sensor coolant From 5D779021 1
Show fields from Show fields from Show fields from a related table
Report Name *
Description
Reports and Charts Panel
Each table has a panel listing its reports and charts, organized in groups.
Please wait while your new report is saved...
Field label
Column heading override
Justification
What does auto mean?
Fields in:

Fields to Extract:

Name for the new table:
Items in the new table are called:

When you bring additional fields into a conversion, Quickbase often finds inconsistencies. For example, say you're converting your Companies column into its own table. One company, Acme Corporation, has offices in New York, Dallas and Portland. So, when you add the City column to the conversion, Quickbase finds three different locations for Acme. A single value in the column you're converting can only match one value in any additional field. Quickbase needs you to clean up the extra cities before it can create your new table. To do so, you have one of two choices:

  • If you want to create three separate Acme records (Acme-New York, Acme-Dallas and Acme-Portland) click the Conform link at the top of the column.
  • If the dissimilar entries are mistakes (say Acme only has one office in New York and the other locations are data-entry errors) go back into your table and correct the inconsistenciesin this case, changing all locations to New York. Then try the conversion again.

Read more about converting a column into a table.